DIVLABS Trinity Electrosurgical Unit
With programable micro controller assisted quick response technology
Computerized programable quick response technology monitors the tissue impedance and adjusts the power output to provide the user consistent performance, reducing the need to adjust power settings for different types of tissues. It comes with ten programes for dirrerent specialities. On site program facility possible. Three different modes of cut, coag and bipolar can be stored individually in each program.True digital power readout with dossage error control. Self diagnostic mode with error display (25 error messages) Spark sensor technology and RS- 232 interface.
 
     
 
Advanced Performance Features
  Advanced Safety Features   Enhanced Operating Convenience  
 


Monopolar-computer controlled intelligent cut with Feedback Response System
1. Three Cut Modes - (Auto Cut-optional)

(a) Pure cut suitable for under water cutting (TURP, TUVP & TCRE) with URO-CUT, which eliminates lag time in initiating cut especially suited for urological procedure.

(b) Three Blend-modes (Program)
(c) Low Cut-Endocut (Gastrocut) for G.I. Surgery

2. Three Coag Modes - (Auto Coag-optional)

(a) Desiccation/Soft-for low voltage soft coagulation suitable for laproscopic & delicate tissue work.


(b) Fulgurate/Forced- non contact Coagulation for minimal smoke generation

(c) Spray for non-contact large tissue area coagulation with minimum depth of necrosis.

Bipolar-SLS (Computer controlled Self Limiting System-unmodulated-Auto Optional)

1. Micro- for delicate tissue work by controlled desiccation without charring, adhesion or blanching of adjacent tissue. (opthalmic & nuero-surgery).

2. Macro - for new generation of macro bipolar cutting instruments (Tri-polar) for LAVH procedure etc. When used with BIPOL probes provides excellent tamponade capabilities.

 

1. PPCQM- Patient to Patient plate contact Quality monitoring
technology
- monitors the quality & quantity of contact between the patient & the patient plate. If this contact is not proper the unit deactivates & alarms, thus eliminating any risk of Passive Electrode site burns.

2. It deactivates the unit & alarms in case of any discontiniuity in the patient plate core. Exclusive PEM (Patient Electrode monitoring)

3. Isolated RF output directs current to return back to the generator to reduce the risk of Alternate site burns & to ensure patient safety in case of any discontinuity in patient plate cord. This current has no reference to ground so it does not cause notice able interference with ECG monitor, Cardiac pace maker etc.

4.Independent activation of hand switching, foot switching & bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.

5.Class ‘2’ leakage cancelling, a must for lengthy procedure like Cardiac surgery (CABG) etc.

6. Meets all general requirements of Safety for Electromagnetic compatibility (EMC)as per IEC-60601-1-2 including 36.201 (CISPR 11 Group 1) - Emissions, 36.202-Immunity and 36.202.1-general

 

 


1. Separate Bipolar generator controls and footswitch with auto selectivity reduces the dependency on the operationg room staff during the procedure.

2. Two independent handswitching monopolar outputs and one handswitching bipolar output combined with Laproscopic Clipons, eleminates the need of footswitches during endoscopic procedures.

3.Ergonomically designed trolley to house diathermy, accessories, argon unit with cylinders and smoke evacuator.

4. Comprehensive clinical training network through workshops, seminars, videos & literatures.

UPGRADATIONS

1. Vessel Sealing System both for open and Laparscopic Surgeries - TRINITY-LS

2. Upgradation into Dual Generator System for C.T.V.S. Surgeries with specialised IMA-program (Internal Mammary Artery Harvesting) and vessel sealing system for Endo Vessel Harvesting TRINITY-CT.

3. Easly upgradable into Argon-Beamer with DIV-ARGON Module with DIV-ARGON Module

4. Compatible with DIV-VAC smoke evacuator

5. Upgradable with DIV-BCM Bipolar current minotor

6. Compatiable with DIC-AES Active electrode safety system

7. Compatible with DIV-RFTA Radio frequency thermal ablation

8. Used with CUSA CEM Module

9. Under Saline BIpolar TURP-TRNITY-NACI

 
     
 
HOME | PROFILE | PRODUCTS | CONTACT US  

 

Partner Sites ::-
http://ligasealer.com , http://quadrf.com , http://plasmaeffect.com , http://rfscalpel.com
Copyright Reserved @ Divlabs(india)2006 design by:. amritadatasoft