Monopolar-computer controlled intelligent cut with Feedback Response System
1. Three Cut Modes - (Auto Cut-optional)
(a) Pure cut suitable for under water cutting (TURP, TUVP & TCRE) with URO-CUT, which eliminates lag time in initiating cut especially suited for urological procedure.
(b) Three Blend-modes (Program)
(c) Low Cut-Endocut (Gastrocut) for G.I. Surgery
2. Three Coag Modes - (Auto Coag-optional)
(a) Desiccation/Soft-for low voltage soft coagulation suitable for laproscopic & delicate tissue work.
(b) Fulgurate/Forced- non contact Coagulation for minimal smoke generation
(c) Spray for non-contact large tissue area coagulation with minimum depth of necrosis.
Bipolar-SLS (Computer controlled Self Limiting System-unmodulated-Auto Optional)
1. Micro- for delicate tissue work by controlled desiccation without charring, adhesion or blanching of adjacent tissue. (opthalmic & nuero-surgery).
2. Macro - for new generation of macro bipolar cutting instruments (Tri-polar) for LAVH procedure etc. When used with BIPOL probes provides excellent tamponade capabilities.
|
|
1. PPCQM- Patient to Patient plate contact
Quality monitoring
technology- monitors the quality & quantity of contact
between the patient & the patient plate. If this contact is not proper
the unit deactivates & alarms, thus eliminating any risk of Passive
Electrode site burns.
2. It deactivates the unit & alarms in case of any discontiniuity in
the patient plate core. Exclusive PEM (Patient Electrode monitoring)
3. Isolated RF output directs current to return
back to the generator to reduce the risk of Alternate site burns & to ensure patient safety in case of any discontinuity in
patient plate cord. This current has no reference to ground so it does
not cause notice able interference with ECG monitor, Cardiac pace maker
etc.
4.Independent activation of hand switching, foot switching
& bipolar output to protect against inadvertent output from an idle
accessory lying on or near the patient or surgical staff.
5.Class ‘2’ leakage cancelling, a must for
lengthy procedure like Cardiac surgery (CABG) etc.
6. Meets all general requirements of Safety for Electromagnetic compatibility (EMC)as per IEC-60601-1-2 including 36.201 (CISPR 11 Group 1) - Emissions, 36.202-Immunity and 36.202.1-general
|
|

1. Separate Bipolar generator controls and footswitch with auto selectivity reduces the dependency on the operationg room staff during the procedure.
2. Two independent handswitching monopolar outputs and one handswitching bipolar output combined with Laproscopic Clipons, eleminates the need of footswitches during endoscopic procedures.
3.Ergonomically designed trolley to house diathermy, accessories, argon unit with cylinders and smoke evacuator.
4. Comprehensive clinical training network through workshops, seminars, videos & literatures.
UPGRADATIONS
1. Vessel Sealing System both for open and Laparscopic Surgeries - TRINITY-LS
2. Upgradation into Dual Generator System for C.T.V.S. Surgeries with specialised IMA-program (Internal Mammary Artery Harvesting) and vessel sealing system for Endo Vessel Harvesting TRINITY-CT.
3. Easly upgradable into Argon-Beamer with DIV-ARGON Module with DIV-ARGON Module
4. Compatible with DIV-VAC smoke evacuator
5. Upgradable with DIV-BCM Bipolar current minotor
6. Compatiable with DIC-AES Active electrode safety system
7. Compatible with DIV-RFTA Radio frequency thermal ablation
8. Used with CUSA CEM Module
9. Under Saline BIpolar TURP-TRNITY-NACI
|
|