DIVLABS Trio Electrosurgical Unit
High performance for most demanding procedures

In the operation theatre, clinic & outpatient surgery centre, the DIVLABS Trio Electrosurgical unit provides a consistently high level of performance and safety. The Trio accepts all standard accessories to help meet the surgeon’s needs in wide range of general procedures and in specialities including cardio-thoracic, urology, neuro-surgery, laproscopic, gynecology, orthopaedic, paediatric, plastic and reconstructive surgeries.
  Advanced Performance Features   Advanced Safety Features   Enhanced Operating Convenience  
 
Monopolar-EPS (Energy
Peak System)

1.
Two Cut modes-
(a) Pure cut suitable for
under water cutting
(TURP, TUVP& TCRE) with
URO-CUT, which eliminates
lag time in initiating cut
especially suited for
Urological procedure.
(b) Three Blend - models
(B-1) Endocut- G. I.
Procedure
(B-2) LLETZ/LEEP
procedure
(B-3) LAPROSCOPIC
procedure

2.
Two Coag modes-
(a) Desiccation for low
voltage soft coagulation
suitable for laproscopic &
delicate tissue work.
(b) Spray for non-contact
large tissue area
coagulation with minimum
depth of necrosis. Bipolar-SLS (Self
Limiting System-
Unmodulated)
1.
Micro- for delicated
tissue work by controlled
desiccation without
charring, adhesion or
blanching of adjacent
tissue (opthalmic & nuero-
surgery)
2.
Macro- for new
generation of macro
bipolar cutting
instruments (Tri-polar)
for LACH procedure etc.
When used with BIPOL
probes provides excellent
tamponade capabilities.
Also suitable for
high-pressure vessel
sealing with Ligation-sure
artery forcep and
bipolar needle ablation.
 

1.PEM (Passive
Electrode Monitoring)
Technology (PPCQM-
Patient to petient plate
contact Quality minitoring
technology) monitors the
quality & quantity of
contact between the
patient & the patient
plate. If this contact is
not proper the unit
deactivates & alarms, thus
eleminating any risk of
Passive electrode site
burns. It also deactivates
the unit & alarms in case
of any discontinuity in the
patient plate cord.

2. Isolated RF output
directs current to return
back to the generator to
reduce the risk of
Alternate site burns & to
ensure patient safety in
case of any discontinuity
in patient plate cord. This
current has no reference
to ground so it does not
cause noticeable
interference with the ECG
monitor, Cardiac pace
maker etc.

3.
Independent activation of hand switching, foor switching & bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.

4. Class ‘2’ leakage
cancelling, a must for
lengthy procedure like
Cardiac surgery (CABG)
etc.

 

1. Separate Bipolar
controls and footswitch
with auto selectivity
reduces the dependency
on the operating room
staff during the procedure.

2. Two independent
handswitching monopolar
outputs and one
handswitching bipolar
output combined
with Laproscopic Clipons,
eleminates the need of
footswitches during
endscopic procedures.

3. Easily upgradable into
Argon beam coagulator
(compatible with Div-argon
Module).

4. Compatible with DIV-
VAC Smoke evacuation unit.

5. Ergonomically designed
trolley to house diathermy,
accessories, argon unit
with cylinders and smoke
evacuator.

6. Comprehensive clinical
training network through
workshops, seminars,
videos & literatures.

7. Smart Modular
Technology for fast &
effective after sales
support (services).

Optional Upgradation

1. Trio-D - Two
independent Monopolar
Hardswitching outputs.

2. Trio-DS-Dual generator
system with two
simultaneous and
independent Monopolar
handswitching outputs
suitable for C.T.V.S


 
TECHNICAL SPECIFICATIONS
 
Partner Sites ::-
http://ligasealer.com , http://quadrf.com , http://plasmaeffect.com , http://rfscalpel.com
Copyright Reserved @ Divlabs(india)2006 design by:. amritadatasoft